Reference · vendors layer v2026-10-08 · 97 companies

Liquid cooling supply chain — who makes what

The industry runs one chain: chips create the heat → cold plates and CDUs capture and move it → couplings and racks hold it together → dry coolers and towers reject it → the facility pays for it. 97 companies across 16 segments, mapped below — each entry links the company's official site; notes state its liquid-cooling role only.

INFORMATION FLOW — 信息流specs · derating curves · BIM models →← demand · site conditions · live telemetry1 · MATERIALS材料与制造· Materials & precision manufacturing32 · COMPONENTS核心部件· Cold plates & in-server cooling5· CDUs13· Quick disconnects & manifolds5· Coolants & chemistry5· Heat rejection6· Pumps, valves & sensors63 · SYSTEMS & SOLUTIONS整机与方案· Chips3· Liquid-ready servers9· Immersion cooling4· Facility cooling & integration7· Small-scale / micro DC54 · DELIVERY & ASSURANCE交付与保障· Solutions & engineering7· Testing & certification45 · BUYERS & OPERATIONS买方与运营· Buyers & operators11BUSINESS FLOW — 业务流(产品与服务交付)→CASH FLOW — 现金流(付款回流)buyers pay colocation / integrators → they pay equipment vendors → vendors pay materials & IPfinancing sits here: equipment leasing · data center REITs · capex deferralSUPPORT LAYER — 支撑体系(不直接交易产品,却约束每一个环节)Standards: OCP · ASHRAE · IEC · SS 726 · CAICTSimulation: 6SigmaDCX · FloTHERMCertification: UL · TÜV · SGSknowledge & data: independent references (this guide) — every claim sourced, curves demandedbusinesscashinformation
FIG. 1 — The full chain, Wei-Zhu canvas style: business flow delivers left→right; cash pays back right→left (financing rides that lane); information runs both ways — specs and curves downstream, demand and telemetry upstream. Numbers = companies per segment in the tables below.

Materials & precision manufacturing (upstream)

Before anyone builds a cold plate: copper and aluminum stock, CNC machining, vacuum brazing, sheet metal — the invisible margin layer of the whole chain.

CompanyHQRole in liquid cooling
Jiangxi CopperCN江西铜业 — copper stock and semi-finished inputs for cold plates and manifoldssite ↗
Chalco (Aluminum Corp of China)CN中国铝业 — aluminum inputs for manifolds, cabinets and heat exchanger finssite ↗
AurubisDECopper semi-finished products into European thermal chainssite ↗

Chips — where the heat starts

Accelerator power is the demand driver: 700-1,000+ W per package made liquid cooling mandatory above ~30 kW/rack.

CompanyHQRole in liquid cooling
NVIDIAUSGB200/GB300-class racks ship liquid-first; the power cliff behind the whole transitionsite ↗
AMDUSInstinct MI300/MI350-class accelerators with liquid-cooled variantssite ↗
IntelUSGaudi/Xeon roadmap with cold-plate-ready packages and OCP contributionssite ↗

Cold plates & in-server cooling

The chip-touching layer: machined/brazed plates, microchannels, heat pipes. Many also build CDUs and full loops.

CompanyHQRole in liquid cooling
CoolIT SystemsCALargest independent cold-plate supplier; also CHx-series CDUs; partner in the 2018 STULZ micro DCsite ↗
AsetekDKCold plates and RackCDU/InRackCDU systems; HPC heritage (listed in Oslo)site ↗
Boyd CorporationUSThermal conglomerate: cold plates, liquid loops, CDUs; high-volume manufacturingsite ↗
Auras TechnologyTWMajor Taiwan cold-plate supplier into AI server ODM chainssite ↗
Wakefield-VetteUSCold plates and heat exchangers, industrial-to-server rangesite ↗

CDUs — pumps & heat exchangers

The heart of every loop: in-rack / in-row / facility CDUs from component level to multi-MW.

CompanyHQRole in liquid cooling
VertivUSCoolChip CDU family (incl. CDU 70 / XDU070 — one of few publishing capacity-vs-ambient curves)site ↗
MotivairUSCDU leader at AI-facility scale; acquired by Schneider Electric (2024)site ↗
CoolIT SystemsCACHx-series in-row CDUs alongside its cold-plate businesssite ↗
Boyd CorporationUSCDUs plus full liquid-loop integration servicessite ↗
AsetekDKRackCDU in-rack systems, liquid-to-liquid focussite ↗
nVentUSRackmount CDUs + Hoffmann edge-rack liquid portfolio (RackChiller)site ↗
DaikinJPApplied CDUs on its refrigeration/HX base; strong in APAC AI hallssite ↗
Delta ElectronicsTWCDUs plus power/thermal integration for AI rackssite ↗
ZutaCoreILTwo-phase direct-to-chip: dielectric fluid boiling on the platesite ↗
JetCoolUSMicrojet impingement plates + cabinet-level liquid systemssite ↗
ChilldyneUSNegative-pressure direct-to-chip: leaks suck air in, not fluid outsite ↗
EnvicoolCN英维克 — China's largest domestic data-center cooling vendor; CDUs and integrated liquid systems for AI hallssite ↗
GoalandCN高澜股份 — liquid cooling for power electronics and data centers; strong domestic AI-facility presencesite ↗

Quick disconnects & manifolds

The interoperability layer: UQD-class couplings and rack manifolds decide whether you can mix vendors.

CompanyHQRole in liquid cooling
StäubliCHDry-break coupling benchmark; OCP UQD-compliant linessite ↗
CPC (Colder Products)USDripless quick disconnects across UQD sizessite ↗
Parker HannifinUSCoolant couplings, hoses and manifold assembliessite ↗
nVentUSORv3-class racks and blind-mate manifold systemssite ↗
RittalDERack/manifold hardware alongside its LCP cooling linesite ↗

Liquid-ready servers (OEM/ODM)

Who ships servers with cold plates and UQD ports pre-installed — the open-ecosystem demand side.

CompanyHQRole in liquid cooling
Dell TechnologiesUSPowerEdge with factory DLC options for AI rackssite ↗
HPEUSCray EX liquid-cooled EX2500/EX2550 blades; long HPC liquid heritagesite ↗
LenovoCN/USNeptune direct liquid cooling across ThinkSystem linesite ↗
SupermicroUSBroad DLC server catalog, liquid-first AI portfoliosite ↗
GigabyteTWLiquid-ready GPU servers for AI/HPCsite ↗
HuaweiCN华为 — liquid-ready rack servers plus facility liquid-cooling lines for AI data centerssite ↗
InspurCNLiquid-cooled AI server lines at hyperscale volumes in CNsite ↗
H3CCNLiquid-ready servers and rack integrationsite ↗
SugonCNImmersion-cooled HPC systems heritagesite ↗

Immersion cooling

Whole-server submersion: single-phase oils or (post-PFAS) engineered dielectrics.

CompanyHQRole in liquid cooling
LiquidStackUSSingle/two-phase immersion at scale; OCP contributionssite ↗
SubmerESSingle-phase immersion pods + SmartCoolant servicessite ↗
GRC (Green Revolution Cooling)USElectroless mineral-oil immersion, longest deployment track recordsite ↗
AsperitasNLImmersed computing in oil, circular-flow designs (image used on our immersion page)site ↗

Coolants & chemistry

PG25 water-glycol dominates direct-to-chip post-PFAS; immersion needs engineered dielectrics.

CompanyHQRole in liquid cooling
DowUSDOWFROST/WF glycol lines behind most PG25-class coolantssite ↗
ClariantCHInhibited glycols and coolant additivessite ↗
DynaleneUSEngineering coolant specialist (glycols, dielectrics, sampling services)site ↗
Engineered FluidsUSSingle-phase immersion dielectrics after the PFAS exitsite ↗
3MUSNovec fluorinated fluids — exited PFAS manufacturing end-2025 (timeline on our radar page)site ↗

Heat rejection — where the heat lands

Dry coolers, towers and heat exchangers: the facility side that L2L loops and free cooling depend on.

CompanyHQRole in liquid cooling
Baltimore Aircoil (BAC)USCooling towers and dry coolers; the evaporative baselinesite ↗
EVAPCOUSDry coolers/adiabatic lines for warm-water loopssite ↗
SPX CoolingUSMarley towers and cooling infrastructuresite ↗
KelvionDEIndustrial heat exchangers and dry coolerssite ↗
Alfa LavalSEPlate heat exchangers — the HX inside many CDUssite ↗
SWEPSEBrazed-plate heat exchangers, compact CDU-scalesite ↗

Pumps, valves & sensors

The quiet layer inside every loop: circulators, control valves, flow/pressure instrumentation.

CompanyHQRole in liquid cooling
GrundfosDKCirculator pumps from server loops to facility scalesite ↗
WiloDEPump groups for cooling circuitssite ↗
DanfossDKValves, controls and sensors for hydronic loopssite ↗
XylemUSBell & Gossett pump/heat-transfer portfoliosite ↗
Dwyer (Ametek)USPressure/flow instrumentation used in loop monitoringsite ↗
TTKFRLiquid leak-detection cable systems for racks and roomssite ↗

Facility cooling & integration

Precision-cooling majors and data center integrators who assemble the room side.

CompanyHQRole in liquid cooling
VertivUSFull-stack: CDUs, chillers, AHUs, micro DCs (VRC-S)site ↗
Schneider ElectricFRUniflair/cooling + EcoStruxure micro DCs; acquired Motivair (2024)site ↗
STULZDEPrecision cooling; 2018 Micro DC with CoolIT still the turnkey benchmarksite ↗
RittalDERacks, LCP air cooling, liquid manifold hardwaresite ↗
MuntersSECooling and climate control for data centers/industrysite ↗
Johnson ControlsUSYork chillers and facility integrationsite ↗
Trane TechnologiesUSChiller plant side of L2L deploymentssite ↗

Small-scale / micro DC (the 20-50 kW frontier)

Our comparison data layer tracks this segment: air-cooled micro DCs stop ~10 kW; liquid turnkey starts at component level. The middle is the gap.

CompanyHQRole in liquid cooling
Schneider ElectricFREcoStruxure Micro Data Center — air, 6U-43U, ~3.5-10 kW classsite ↗
VertivUSVRC-S micro DC (air ~3.5 kW); CoolChip CDU 70 for AI rackssite ↗
STULZ × CoolITDE/CA2018 Micro DC — the only full turnkey liquid micro-cabinet predecessor (27-80 kW)site ↗
nVent / HoffmanUSEdge liquid portfolio: 'add liquid cooling without changing the room'site ↗
AsetekDKInRackCDU 80-120 kW/rack, HPC-oriented, needs tempered watersite ↗

Solutions & engineering (non-equipment)

The non-equipment layer: design institutes, EPC/engineering consultancies, simulation software and certification — plus solution providers who assemble whole liquid-cooling plants across other vendors' hardware.

CompanyHQRole in liquid cooling
Sugon DataEnergy (曙光数创)CN中科曙光旗下 (NEEQ 872808) — full liquid-cooling solutions: cold-plate + phase-change immersion dual track; C8000 immersion rack rated >900 kW/rack; #1 domestic liquid-cooling share five years running (CCID)site ↗
AECOMUSData center design and EPC engineering — the firms that turn cooling physics into buildingssite ↗
WSPCAEngineering consultancy: mechanical/thermal design for data center projectssite ↗
JacobsUSDesign, engineering and program management for mission-critical facilitiessite ↗
Cadence (6SigmaDCX)USData center CFD and digital-twin simulation software (Future Facilities acquisition)site ↗
Siemens (Simcenter FloTHERM)DEElectronics thermal CFD — cold-plate and rack airflow simulationsite ↗
Uptime InstituteUSTier certification and data center consulting — independent of every equipment vendor abovesite ↗

Testing & certification

Independent verification between builders and buyers: safety certification, performance curves, thermal benchmarking — where marketing claims go to be checked.

CompanyHQRole in liquid cooling
UL SolutionsUSSafety certification incl. liquid-cooling components (UL mark)site ↗
TÜV RheinlandDECE-route testing and performance verification for EU deploymentssite ↗
SGSCHInspection, testing and certification servicessite ↗
CAICT (中国信通院)CNChina Academy of Information and Communications Technology — domestic liquid-cooling evaluation and standards worksite ↗

Buyers & operators — where the money starts

The demand the entire chain exists for: hyperscalers, clouds, telcos and colocation — their rack-power roadmaps set every upstream design decision.

CompanyHQRole in liquid cooling
AWSUSHyperscale demand driver; custom rack programs reach 100+ kWsite ↗
Microsoft AzureUSLiquid-cooled AI infrastructure at hyperscalesite ↗
Google CloudUSTPU pods and GPU fleets push liquid-first rack designssite ↗
Alibaba Cloud (阿里云)CN浸没式液冷规模化部署的先行者(仁和数据中心)site ↗
Tencent Cloud (腾讯云)CNT-Block 与液冷数据中心批量部署site ↗
China Mobile (中国移动)CN运营商智算中心集采——国产液冷链的最大单一买方之一site ↗
EquinixUSColocation; xScale JV builds for hyperscale tenantssite ↗
Digital RealtyUSGlobal colocation platform tracking high-density liquid deploymentssite ↗
GDS (万国数据)CN头部第三方 IDC,液冷智算集群批量落地site ↗
VNET (世纪互联)CN第三方 IDC 与智算中心运营商site ↗
Chindata (秦淮数据)CN超大规模数据中心园区,东南亚/中国液冷部署site ↗

Standards & industry bodies

Who defines interoperability and safety — cite them in every RFQ.

CompanyHQRole in liquid cooling
Open Compute Project (OCP)USUQD couplings, ORv3 racks and blind-mate manifoldssite ↗
ASHRAEUSW-class facility-water temperature frameworksite ↗
IECCHIEC 62368-1 Ed.4 — electrical safety incl. liquid clausessite ↗
Enterprise SingaporeSGSS 726:2026 — first tropical liquid cooling standardsite ↗

Reading the map

  • Consolidation is real: Schneider acquired Motivair (2024); several majors bought their way into CDUs. Ownership shifts faster than this page — verify before contracting.
  • Interop lives in the middle boxes. If your cold plates, CDU and couplings all speak OCP (UQD, ORv3), you can mix rows across vendors — that is the whole lock-in defense (UQD table).
  • The 20-50 kW frontier is thin. The micro-DC segment below still shows the gap our comparison data documents — air cabinets stop ~10 kW, liquid turnkeys barely exist.

List your company

Missing from the map, or wrong? Listings are free, editorially reviewed, and never paid — independence is this site's product. Email [email protected] with the fields below (the template is pre-filled if you click), and we verify against an official source before anything enters the data layer:

Company: ____
HQ (country): ____
Segment (one of the 16 above): ____
Role in liquid cooling, one line: ____
Official site URL: ____
Source URL verifying it (product page / datasheet): ____

Corrections to existing rows go to the same address. Listing is not an endorsement; the changelog records every data-layer change.

Related

Cabinet comparison · RFQ scope checklist · UQD quick disconnects · Standards

Sources & policy

Company roles per their official sites (linked per row); segment placement reflects each company's liquid-cooling-relevant business as of 2026-10-08. No funding, revenue or market-size claims — out of facts-policy scope. Corrections via the changelog.